Page 210 - CRS Engineering
P. 210
ANNEXURE - II
PROFORMA FOR SUBMISSION OF R.A.T INSPEaiON REPORTS
S.No Description Remarks
1 General Particulars of RAT
1 Name of the Tank Venkatapuram Tank
2 District Chittoor
3 Name of the Village and Mandal Venkatapuram & Renigunta
4 Latitude & Longitude 13°39' 40.08"and 79°29'36.74"
Bridge No.204@137/14-16 & Bridge
5 Affected Railway Bridge and KM No.206 @ 138/17-19
6 Railway section in between stations Renigunta to Koduru
Distance from RailwayBridgeto Bund(along the
1.70 Km
7 Course of Nallah)
II Standard Hydraulic details
1 Catchment area 7.89 Sq.Km
2 Capacity of the tank 19.35 Mcft
3 Lowest Bed Level 96.12
4 FullTank Level (FTL) 100.00
5 Maximum Water Level (MWL) 100.90
6 Danger Level (DL) 101.50
7 Top Bund Level 102.10
8 Top width of the Bund 2.2 M
9 Side Slopes U/S 2:1 & D/S2:1
10 Area of submergence at FTL 68.00 Acres
11 Area of submergence at MWL
Arethere any Tanksinthe catchment Area of
Yes
12 this tank
13 Are these tanks also classified as RAT's No
14 Name and details of these tanks
III Surplusweir
1 No of Surplusweir INo
2 Lengthes 40.00 M
3 Type of Surplusweir N.CWeir
4 Design Discharge 2769 Cusecs
IV Sluices
1 No of Sluices 2 No's
1)275 M
2 Location of Sluices
2)540 M
3 Maximum Level discharge 2 X 24 Cusecs
4 Functional or not Functional
V A Inspection details
i) Date of Inspection 14-02-2020
1) Sri.C'Vlilson Babu
ii) Name & Designation of the inspection officials
Assistant Divisional Engineer