ANNEXURE - II

                              PROFORMA FOR SUBMISSION OF R.A.T INSPEaiON REPORTS

               S.No                    Description                                   Remarks
                1     General Particulars of RAT
                1     Name of the Tank
                                                                              Thimmalahgunta Tank
                2     District
                                                                                     Chittoor
                3     Name of the Villageand Mandal
                                                                           Thimmalahgunta &Renigunta
                4     Latitude&Longitude
                                                                            13°39'00"and 79° 30'00"
                5     Affected Railway Bridge and KM                        Bridge No.200 @135/41-43
                6     Railwaysection in between stations
                                                                               Renigunta to Koduru
                      Distance from Railway Bridge to Bund(along the
                7     Course of Naliah)                                             1.00 Km
                11    Standard Hydraulic details
                1     Catchment area                                               2.49 Sq.Km
                2     Capacity of the tank                                          7.95 Mcft
                3     Lowest Bed Level
                                                                                     97.20
                4     Full Tank Level (FTL)
                                                                                     100.00
                5     Maximum WaterLevel (MWL)
                                                                                     100.90
                6     Danger Level (DL)
                                                                                     101.50
                7    Top Bund Level
                                                                                     102.10
               8     Top width of the Bund
                                                                                     1.7 M
               9     Side Slopes
                                                                               U/S 1.5:1 &D/S 2:1
               10    Area of submergence at FTL
                                                                                  56.00 Acres
               11    Areaof submergence at MWL
                     Arethere anyTanksinthe catchment Areaof
               12    this tank                                                        Yes
               13    Arethese tanks also classifiedas RAT's
                                                                                      No
               14    Name and details of these tanks
               III   Surplusweir
               1     No of Surplusweir
                                                                                     INo
               2     Lengthes        ^
                                                                                    15.00 M
               3     Type of Surplusweir                                           B.CWeir
               4     Design Discharge
                                                                                  1356 Cusecs
               IV    Sluices
               1     No of Sluices
                                                                                    3 No's
               2     Location of Sluices                                           1) 175 M
                                                                               2)365 M 3)600 M
               3     Maximum Level discharge
                                                                                 3 X 18 Cusecs
               4     Functional or not
                                                                                     Not
             V  A    Inspection details
               i)    Date of Inspection
                                                                                  14-02-2020

              ii)     ame &Designation ofthe inspection officials             1) Sri.c-VMilson Babu
                                                                          Assistant Divisional Engineer