Page 216 - CRS Engineering
P. 216

ANNEXURE - II
                            PROFORMA FOR SUBMISSION OF R.A.T INSPEaiON REPORTS

            S.No                    Description                                   Remarks
              1     General Particulars of RAT
              1     Nameof tlielanlc                                        Madigavanlgunta Tank
              2     District                                                      Chittoor
              3     Name of the Village and Mandal                       Madigavanigunta & Renigunta
              4     Latitude & Longitude                               13°38' 35.07" and 79° 29' 31.73"
              5     Affected Railway Bridgeand KM                         Bridge No.200 @135/41-43
              6     Railway section in between stations                      Renigunta to Koduru
                    Distance from Railway Bridge to Bund(along the
                                                                                   1.7 Km
              7     Course of Nallah)
              II    Standard Hydraulic details
              1     Catchment area                                              0.937 Sq.Km
              2     Capacity of the tank                                          3.53 Mcft
              3     Lowest Bed Level                                               97.12
              4     FullTank Level (ITL)                                           100.00
              5     Maximum Water Level (MWL)                                      100.90
              6     Danger Level (DL)                                              101.50
              7     Top Bund Level                                                 102.10
              8     Top width of the Bund                                          2.0 M
              9     Side Slopes                                               U/S 1.5:1 & D/S 2:1
             10     Area of submergence at FTL                                   40.00 Acres
             11     Area of submergence at MWL
                    Are there any Tanks in the catchment Area of
                                                                                    Yes
             12     this tank
             13     Are these tanks also classified as RAT's                         No
             14     Name and details of these tanks
             III    Surplusweir
              1     No of Surplusweir                                              2 No's
              2     Lengthes                                                      20.50 M
              3     Type of Surplusweir                                     N.CWeir & B.C.Weir
              4     Design Discharge                                             653 Cusecs
             IV     Sluices
              1     No of Sluices                                                   INo

                                                                                  1) 350 M
              2     Location of Sluices

              3     Maximum Level discharge                                       18 Cusecs
              4     Functional or not                                               Not
            V  A    Inspection details
              i)    Date of Inspection                                           14-02-2020

                                                                             1) Sri.C'MMilson Babu
             ii)    Name & Designation of the inspection officials
                                                                         Assistant Divisional Engineer
                                                                        Southern Railway, RENIGUNTA