ANNEXURE -II
PROFORMA FOR SUBMISSION OF R.A.T INSPEaiON REPORTS
S.No Description Remarks
1 General Particulars of RAT
1 Name of the Tank Patha Renlgunta Tank
2 District Chittoor
3 Name of tiie Village and Mandal Renigunta Agraharam & Renigunta
4 Latitude & Longitude 13°38' 50.10"and 79°30' 35.07"
Bridge No.200 @135/41-43 &
Bridge No.201 @136/8-10 & Bridge
5 Affected Railway Bridgeand KiVI No.206 @136/14-16
6 Railway section in between stations Renigunta to Koduru
Distance from Railway Bridge to Bund(aIong the
100 Mts
7 Course of Nallah)
II Standard Hydraulic details
1 Catchment area 0.906 Sq.Km
2 Capacity of the tank 6.61 Mcft
3 Lowest Bed Level 97.20
4 Full Tank Level (ITL) 100.00
5 Maximum Water Level (MWL) 100.60
6 Danger Level (DL) 101.75
7 Top Bund Level 102.10
8 Top width of the Bund 2.0 M
9 Side Slopes U/S 1.5:1 & D/S 2:1
10 Area of submergence at FTL 25.83 Acres
11 Area of submergence at MWL
Are there any Tanks in the catchment Area of
Yes
12 this tank
13 Are these tanks also classified as RAT's Yes
14 Name and details of these tanks Thimmaiahagunta Tank & Venkatapuram Tank
III Surplusweir
1 NoofSurplusweir INo
2 Lengthes 20.00 M
3 Type of Surplusweir N.CWeir
4 Design Discharge 637 Cusecs
IV Sluices
1 No of Sluices INo
2 Location of Sluices 1)250 M
3 Maximum Level discharge 18 Cusecs
4 Functional or not Functional i
V A Inspection details
i) Date of Inspection 14-02-2020
1) Sri.C^Nilson Babu
ii) Name &Designation of the inspection officials
Assistant Divisional Engineer
Southern Railway, RENIGUNTA