Page 214 - CRS Engineering
P. 214

ANNEXURE - II
                             PROFORMA FOR SUBMISSION OF R.A.T INSPEaiON REPORTS

              S.No                    Description                                  Remarks
                1    General Particulars of RAT
               1     Name of the Tank                                          Annasampalli Tank
               2     District                                                       Chittoor
               3     Name of tfie Village and Mandal                       Annasampalli & Renigunta
               4     Latitude & Longitude                                13°38' 53.44" and 79° 29' 18.37"
               5     Affected Railway Bridge and KM                        Bridge No.200 @135/41-43
               6     Railway section in between stations                      Renigunta to Koduru
                      Distance from Railway Bridge to Bund(along the
                                                                                    2.10 Km
               7     Course of Nallah)
               II    Standard Hydraulic details
               1     Catchment area                                               1.48 Sq.Km
               2     Capacity of the tank                                          8.40 Mcft
               3     Lowest Bed Level                                                97.12
               4     FullTank Level (FTL)                                           100.00
               5     Maximum Water Level (MWL)                                      100.90
               6     Danger Level (DL)                                              101.50
               7     Top Bund Level                                                 102.10
               8     Top width of the Bund                                           1.7 M
               9     Side Slopes                                               U/S 1.5:1 & D/S 2:1
               10    Area of submergence at FTL                                   65.00 Acres
               11    Area of submergence at MWL
                     Are there any Tanks in the catchment Area of
                                                                                      Yes
               12    this tank
               13    Are these tanks also classified as RAT's                         No
               14    Name and details of these tanks
               III   Surplusweir
               1     No of Surplusweir                                               INo
               2     Lengthes                                                       22.00 M
               3     Type of Surplusweir                                            B.CWeir
               4     Design Discharge                                             921 Cusecs
               IV    Sluices
               1     No of Sluices                                                   2 No's

                                                                                   1) 300 M
               2     Location of Sluices
                                                                                    2)500 M
               3     Maximum Level discharge                                     2 X 18 Cusecs
               4     Functional or not                                             Functional
              V  A    Inspection details
               i)    Date of Inspection                                           14-02-2020
                                                                              1) Sri.C-V^ilson Babu
               ii)   Name & Designation of the inspection officials
                                                                          Assistant Divisional Engineer
                                                                         Southern Railway, RENIGUNTA