Page 28 - Foton Workshop Manual - Auman EST-M
P. 28

IN - 22                  Introduction - General rules for maintenance and operation

              3. Remove or install the parts of fuel control system.

              a. Instructions for work site for removing or installing the parts of fuel system
              ● Be sure to select the well-ventilated site, and ensure no equipment or objects possible to cause open fire
              around it, including welding machines, grinder, electric drill, motor and oven.
              ● Don’t select any filling station or its adjacent area, because the evaporated fuel may be full of whole space.

              b. Remove or install the parts of fuel system.
              ● Prepare for the fire extinguisher before starting the operation.

              ● In order to avoid static electricity, it’s required to ground the vehicle or fuel tank, etc and keep the workshop
              ground dry to avoid slipping.

              ● Don’t apply any electric appliance like motor or working lamp to avoid spark or high temperature.
              ● Don’t use any iron hammer to avoid any spark.
              ● Use a fireproof container to store the fuel-soaked rags.
              4. Remove or install the parts of engine air inlet system.

                                                           Caution
              If the fastener is broken during service, must replace it with a new one

              ● In case of removing or installing the parts of air inlet system, seal the openings of removed parts with
              a clean rag or tape.
              ● In case of installing the parts of air inlet system, be sure to confirm no metal chippings on them.


                                                        5. Operation of hose hoop
                                      Spring hoop
                                                        a.  Before  removing  the  hose,  check  the  depth  of  plug
                                                        insertion and hoop position to re-install them correctly.

                                                        b. If the hose is deformed or notched, replace it.
                                                        c. If the hose can be reused, be sure to clip the spring hoop
                                                        into original notch.
                  Hoop mark                             d. For any spring hoop, adjust its position in the direction of
                                                        arrow after installing it.

              6. Attentions for engine oil
              Overlong and repeated contact with used oil may cause skin cancer, so direct contact of skin with used oil
              shall be avoided as much as possible. If the skin has contacted it, clean it thoroughly with a soap or cleaning
              fluid as soon as possible.

              Deliver the used engine oil and its filter to the specified handling facility or used oil exchange. If any doubt,
              you can consult with local officials about its handling.
              It’s  illegal  to  pour  the  used  oil  on  the  ground,  into  the  sewage  pipe  or  sewer.  The  regulations  related  to
              environmental pollution may be changed in different countries.
              7. Attentions for A/C system
              When the refrigerant of A/C system must be drained, it’s required to use the refrigerant recovery unit.
              8. Attentions for jack operation

              a. Be sure to check whether the parts of jack are normal before the operation.


                                                          IN-022