                                                      Diagnosis-Power Windows
               4.     Checking for air cleaner indicator light signal circuit open

                                                                (a)     Use a multimeter to measure voltage to
                                                                        ground of connector pin 19 of
                                                                        combination meter B033.
                                                                        Voltage: battery voltage










               Is check result normal?
   4           Yes >   Repair signal line open between connector pin 1 of air cleaner clogging warning light switch
                      C011 and connector pin 19 of combination meter B033.
               No >    Replace combination meter assembly.