Page 49 - GuardII+ Series 4208 Platform User Manual
P. 49

User Instructions
































                                               Figure 6-13 IAM Device Utilities

              6.6.1.  Reboot Instrument
                        This utility will simply re-start the GuardII+.  Once the utility is run, it will take a few minutes
                     before the monitor will start taking measurements again.

              6.6.2.  Delete Archives

                        This utility will delete all the Archives that are currently saved on the GuardII+.  This does
                     not  affect  the  current  state  of  the  Triggers  or  measurements  that  have  already  been
                     downloaded and/or imported into the computer with the IAM software; only measurement data
                     that is stored in the monitor is deleted.

                                     WARNING:
                                     Once the Archive is deleted in the GuardII+, it cannot be restored; do not
                                     use this utility unless you are sure that you do not need the Archived data
                                     anymore.


              6.6.3.  Clear Trigger History
                        GuardII+  uses  Triggers  to  determine  when  to  archive  data;  the  Triggers  analyze
                     measurement results looking for specific data patterns and storing data that matches those
                     patterns.    This  utility  will  reset  the  Trigger  analysis  for  all  monitoring  technologies.    The
                     GuardII+ will begin taking measurements as if no Triggers have ever occurred before.  This
                     does not affect the Archived or downloaded measurements; it only resets the Triggers.

                                     WARNING:
                                     Once the Triggers are reset in the GuardII+, they cannot be restored back
                                     to the previous status; do not use this utility unless you are sure that you
                                     want to start the Triggers over again.