4.3.2 Electrical Services
       •  All electrical contractors employed on ANY         •  All  wiring  and  cable  containment  shall  be
          Domino’s site, whether self-build or DP UK&I           concealed  within  the  building  fabric  and
          Ltd build, MUST be NICEIC certified.                   within the false ceiling void.
       •  The  project  includes  all  of  the  Electrical   •  All wiring must be run in suitable conduits or
          Services work associated with the fitting out          cable trays.
          of an existing unit to create a fully operational   •  Final locations of all outlets and equipment
          Domino’s pizza delivery store.                         shall  be  in  accordance  with  the  DGP
       •  The Electrical Contractor shall be responsible         Standard layouts and fully coordinated
          for detailed design, supply, installation, co-         with other  trades. Any deviations  from the
          ordination with other disciplines, testing and         standard  details  must  be  agreed  with  the
          commissioning for all items as detailed in this        Project Manager/Client prior to installation.
          specification and accompanying drawings.           •  All  wiring,  including  computer,  telecoms
       •  Existing  and  new  stores:  contractor  must          and electrical, within the counter,  shall be
          provide isolator before board and meter.               run  in  suitable  trunking  terminated  through
       •  All works shall be carried out in accordance           standard  boxes.  It  is the  responsibility of
          with the latest relevant British and European          the  Main  Contractor  to  ensure  that  this
          Standards  including  BS7671  (18th    Ed  IEE         is  complied  with  by  his  electrical  sub-
          Wiring  Regulations  or subsequent  updates/           contractor.
          revisions), current at the time of installation.   •  Data and telecoms cables  must each
                                                                 emerge from walls/trunking in suitable back
       The works shall include:                                  boxes and be positioned so that standard
       •  Removal  and  disposal  of  any  existing              modular face plates may be fitted.
          redundant installations.                           •  Earth  bonding  of  fixed  metal  equipment
       •  Mains distribution equipment.                          shall  be  carried  out  by  the  site  electrician
       •  General lighting.                                      as required by the Regulations.
       •  Emergency lighting.                                •  Installation  of  RCBO’s  is  expected  where
       •  External lighting.                                     “Best  Practice”  would  call  for  their  use,
       •  Small power.                                           even in discretionary or ‘grey areas’ of the
       •  Fixed power to equipment and signage.                  regulations.
       •  Computer cabling.                                  •  Final circuit testing MUST be in full compliance
       •  Fire Alarm.                                            with the appropriate regulations.
       •  Telephone wiring.                                  •  O&M  manual,  testing  and  commissioning
       •  Door bell.                                             certificates   must   be    provided     upon
       •  Testing and commissioning.                             completion of a project.
       •  Provision of record documentation.
       •  User/Client demonstration and training.








       4.3.2                       Electrical Services                                   30 May 2018