                       Installation


                       Standard Water Manifolds

                          Locate the following items:
                              •   (1) Section of water hose
                              •   (3) Barbed hose fittings
                              •   (3) Hose clamps.
                          Water Manifolds Assembly
                              1)  Locate the barbed hose fittings. Secure one to opening on the underside of each manifold. This is
                                 how one manifold will be fed from the other.
                              2)  Secure the other fitting to the end of the vertical manifold. This is the main water feed.
                                                                                       Overhead View



                                               Clamp (typical)   Crossbeam   Water feed













                                                                                        ®
                              Note:  Fittings require a water sealant. We recommend using Teflon  tape, pipe dope or an
                                     equivalent.
                              3)  Locate the hose clamps and slide two of them onto the supplied 3/4” water hose, use the water
                                 hose to connect the two manifolds together and slide the hose clamps into position.
                                                                                                        Barbed hose
                                         Barbed hose                                                    fitting (typical)
                                        fitting (typical)
                                                                                                        Hose Clamp
                                                                                                        (typical)

                                         Hose Clamp
                                            (typical)








                                               Use Teflon® Tape on the threads of the barbed hose fittings
                              4)  Slide the third hose clamp onto the hose being used as a main water feed and secure the main
                                 water feed hose to the vertical manifold. Slide the hose clamp into position.