Page 30 - Hydro-Hybrid™
P. 30

HYDRO HYBRID™


            Installation


            Utilities

               Overview
                The Hydro Mitter requires 32 GPM @ 100PSI working pressure. The main water feed manifolds are split into two
                chambers. The top manifolds and the two middle manifolds should have six nozzles total. The six nozzles equal 15
                GPM @ 1000PSI. The two 1” MNPT ports should be tied together to feed the top manifolds and the two middle
                manifolds. The two lower manifolds have the four “spinner” nozzles. These have a total of 16 nozzles which equal 16
                GPM @ 1000PSI. The two ports that feed the lower manifolds should also be tied togther.

                   Note:  It is recommended that a licensed technician is contracted to perform all utility
                          installations.
                   Main high-pressure, water feeds                              Main high-pressure, water feeds










                         High-pressure                                               High-pressure
                        water manifold                                               water manifold



























                   Note:  See High-Pressure Manifold Overview for more details.



















              28        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681         1MANUL253