Page 26 - Saber® Installation & Startup
P. 26

INSTALLATION & STARTUP

            Chapter 3 Getting Started



            Size Limit Options to Consider

               Height Considerations
               If  height  becomes  a  restriction  in  fitting  a  Saber®  into  a  bay  then  consider  the  following
               compromises.
                Option #1: Lower the maximum vehicle height by up to 4”

                 The maximum vehicle height is 84’’ for a standard installation. Reducing the maximum vehicle
                 height down to 80’’ to fit into a 126’’ high bay can be done. This will leave approximately 5-1/4’’
                 clearance from the bottom of the manifold to the floor. If this is the option that you plan to use,
                 then the frame and Boom Mount will have to be lowered down to the desired height. This will
                 require a field supplied “height bar” to inform the customers at the entrance of the wash bay to
                 be lowered down to 80’’ to accommodate the new maximum vehicle height. You should NEVER
                 lower the whole machine more than 4” for proper sonar operation. Set the sonar parameters in
                 the HMI E-1063 per the Saber® Programming Manual. Consider manifold height once again if a
                 DuraShiner® CF will be placed at the exit under the arms.
                Option #2: No On-Board Dryer
                 If the bay height is still a restriction when considering option number 1, you may not be able to
                 use  the  On-Board  Dryer  option.  If  you  do  not  have  an  On-Board  Dryer,  the  overall  machine
                 height is lower by 5-1/2’’. If this is an option that you plan to use, the boom height will also need
                 to be adjusted down 5-1/2 inches.
                Summary
                 If option 1 and 2 are both utilized, the minimum building height the Saber® can fit into is 120-
                 1/2’’. In addition, if the building length is not a restriction then a Belanger AirBlade Dryer system
                 can be installed. The overall height of the AirBlade Dryer system is lower than the Saber® On-
                 Board  Dryer  height  and  needs  to  be  placed  outside  of  the  travel  and  butterfly  motion  of  the
                 Saber® manifolds. These systems will fit into a bay that is 120-1/2’’ inches tall, which is the new
                 minimum height of the machine when both option 1 and 2 are utilized for installation.



































             3-2    Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681      1MANUL290