                      Size Limit Options to Consider

                          Width Considerations
                          The minimum building width is 12 feet–3 inches and can not be compromised because the frame
                          is not the ONLY restriction that limits the width. The side manifold deflection under high pressure
                          is a definite restriction and can not be allowed to deflect into the wall of the wash bay.
                          The side walls must be free of all obstructions to a width of 12 feet–3 inches total, 6 feet-
                          1-1/2 inches from the Saber centerline.
                          If Belanger Side Kick® dryers are to be installed 14 feet–8 inches is the minimum width at the
                          exit end,. All of the width considerations and options are described in more detail in chapter 6.
                          The maximum width is 17 feet wide when using the headbeams from our standard Wall Mounted
                          and Floor Mounted Frames.
                          A maximum width of 19 feet can be achieved when using our “optional” longer headbeams.




                                   Due to weight restrictions, this option can NOT accommodate Side Kick® Dryers.
                                        A separate wall mount can be purchased to mount Side Kick® Dryers.

                          Length Considerations

                          If building length becomes a restriction, there are a few options available for fitting the system
                          into a shorter bay. These options can be used individually or together to accommodate most bay
                          length restrictions. In addition it is important to note that there are compromises that need to be
                          considered  for  each  option.  The  image  below  shows  the  areas  that  will  require  consideration
                          when installing into a shorter bay.
                                  Exit                                                  Entrance
                              Headbeam                                                  Headbeam
                             and End Stop                                               and End Stop


                              Exit                                                          Entrance
                            Manifold                                                        Manifold
                            Butterfly   Exit                                       Entrance   Butterfly
                                   Photo-Eyes                                      Photo-Eyes



                                                       Maximum Vehicle Length

                          The  following  pages  will  provide  detailed  explainations  of  the  components  that  comprise  the
                          Saber® working envelope. Review all corresponding pictures during the explanations.