Page 72 - Saber® Installation & Startup
P. 72
INSTALLATION & STARTUP
Chapter 6 Frame and Carriage Assembly
Frame Assembly (Wall Mounted)
Preparing the Wall Mounts
Note: For bay widths that fall in between the measurments stated above, it may be necessary to
slide the wall mount bracket in or out to fit. Keep in mind that after the final cuts have been
made, there should never be less than 1-1/2’’ from back of wall mount clamp to the end of
the head beam. See image below for example.
1-1/2”
minimum
To properly fit the frame into the wash bay, the Wall Mount Brackets will likely need to be cut.
Follow the image/chart below to determine required size to accommodate your bay width
before assembly begins.
Bay Width Wall Mount Bracket Length Head Beam Length
17 Feet to 16 Feet 30'' 164''
16 Feet to 15 Feet 24'' 164''
15 Feet to 14 Feet 18'' 164''
14 Feet to 12Feet 3in 12'' 4” shorter than the bay width
6-10 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL290