Page 72 - Saber® Installation & Startup
P. 72

INSTALLATION & STARTUP

            Chapter 6 Frame and Carriage Assembly



            Frame Assembly (Wall Mounted)

               Preparing the Wall Mounts













                   Note:  For bay widths that fall in between the measurments stated above, it may be necessary to
                          slide the wall mount bracket in or out to fit. Keep in mind that after the final cuts have been
                          made, there should never be less than 1-1/2’’ from back of wall mount clamp to the end of
                          the head beam. See image below for example.



                                                    1-1/2”
                                                    minimum










                  To properly fit the frame into the wash bay, the Wall Mount Brackets will likely need to be cut.
                  Follow  the  image/chart  below  to  determine  required  size  to  accommodate  your  bay  width
                  before assembly begins.
                             Bay Width     Wall Mount Bracket Length   Head Beam Length
                          17 Feet to 16 Feet        30''          164''
                          16 Feet to 15 Feet        24''          164''
                          15 Feet to 14 Feet        18''          164''
                          14 Feet to 12Feet 3in     12''          4” shorter than the bay width



















             6-10   Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681    1MANUL290