Page 74 - Saber® Installation & Startup
P. 74

INSTALLATION & STARTUP

            Chapter 6 Frame and Carriage Assembly



            Frame Assembly (Wall Mounted)

               Installing the Wall Mount Clamps and Carriage
                   1)  Locate the four Wall Mount Clamps and slide them on the ends of the head beams as shown below. Do not
                      fully tighten them until instructed to do so.





                                                         Typical










                   2)  Measure a distance of 101-3/4’’ up from the ground at the lowest point in the wash bay and mark a line on
                      the wall the length of the bay.






                                                                   101-3/4”
                                                                   From closest point of the floor
                                                                   allowing for a slopped floor.
                                                                   This will result in 106-1/2“
                                                                   minimum height under the
                                                                   headbeam.
































             6-12   Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681    1MANUL290