Page 58 - Sudzameleon® Arch
P. 58
®
SUDZAMELEON ARCH
Maintenance
Routine Procedures
Sudzameleon® Arch (Daily)
Clean and inspect the wash tunnel for debris.
Inspect all chemical levels. Replace as necessary.
Inspect all lights and signage. Clean or replace as necessary.
Visually check the spray of each of the nozzles. Clean or replace as necessary.
Visually inspect all hoses and airlines for damage or wear. Replace as necessary.
Inspect the arch for clogged nozzles. This can best be done while running a test vehicle at the
start of the business day. Insert a thin wire into the nozzle opening to clear any obstructions.
Sometimes simply tapping on the nozzle can clear it.
Run a test wash
Sudzameleon® Arch (Monthly)
Inspect all fasteners and anchors on the frame and any additional components.
Inspect the air pressure on the air panel regulators. Adjust as necessary.
Wash component down with a good degrimer such as Tide laundry detergent and hot water.
Support Equipment
For any equipment NOT supplied by Belanger®, refer to the corresponding manual for any
maintenance procedures or additional recommended or needed activities.
Drain any water out of the air compressor tank according to the manufacturer’s
recommendations.
For any equipment supplied by Belanger®, refer to the supplied Belanger® manuals.
®
®
If using a Belanger MixStir to supply the Foam Bullets® refer to that manual (1MANUL450)
for troubleshooting any issues and to diagnose any repair or maintenance issues.
®
If using a Belanger supplied Pulsatron pump assembly with air panel which is a Auto Fluid
Injection System (AFIS) to supply the Foam Bullets® refer to that manual (1MANUL006) for
troubleshooting any issues and to diagnose any repair or maintenance issues.
54 Belanger, Inc.® *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL956