Page 75 - Best Practices In Knowledge Transfer Programme(KTP) Phase 1
P. 75

IMPLEMENTATION OF                                            INFORMATION OF INDUSTRIAL / COMMUNITY PARTNER
      AREA OF EXPERTISE
     PROJECT                               AREA OF EXPERTISE       NO.  ITEM            DETAILS
       NO.
           LEADER / AKADEMICIAN /GI
        1.  ASSOC. PROF. DR. KAMARUL HAWARI  BIN   SCIENCE AND ENGINEERING    1.    COMPANY’S NAME   QMEC CONSULT SDN BHD
           GHAZALI                         I                                          (952590-D)
        2.  ASSOC. PROF. DR. SUZAIMAH BINTI RAMLI  MAGE PROCESSING
        3.  ASSOC. PROF. DR. MUHAMMAD SHARFI BIN  GAS SENSOR       2.    NAME OF OWNER /    IR. AZHAR SAFII IR
           NAJIB                                                          MANAGER
        4.  TUAN SAIYED RASOL BIN TUAN MUDA   TELECOMMUNICATION    3.    BUSINESS ADDRESS AND   K 8813-E2, LEVEL 1, BANGUNAN MPK,
                                                                          PHONE NUMBER
        5.  MR. MOHD SHAWAL BIN JADIN      THERMAL IMAGING                            24300 KERTIH, KEMAMAN,
                                                                                      TERENGGANU DARUL IMAN
        6.  DR. AMIR IZZANI BIN MOHAMED    HIGH VOLTAGE
        7.  MS. AMINAH ALINA BINTI IBRAHIM  GRADUATE INTERN        4.    NUMBER OF STAFF     15
                                                                   5.    NUMBER OF
                                                                                      100
        8.  MS. AUFA HUDA BINTI IBRAHIM    GRADUATE INTERN                BENEFICIARIES

     Best Practices in KTP
     IMPLEMENTATION OF
     PROJECT



          Objectives       1.  To  transfer  the  technology  and  knowledge  on  gas  leakage  detection  using  newly  and  advance
                              thermal camera system. The integration system of hardware thermal camera and detection system
                              software will be installed at the dedicated location recommended by industrial partner.
                           The  program  will  be  started  with  integration  of  software  and  hardware  to  become  a  complete
          Methodology      system of monitoring and detection. All the information of process plant physical such as design, layout
                           equipment and piping will be used to locate the system in the plant. The complete system; thermal
                           camera hardware and software will be installed at the location recommended by industrial partner. The
                           system will be operated throughout the year to do real time monitoring and detection of gas leakage.

          Activities       1.  Visualize gas in real time.
          Conducted        2.  Pinpoint the location.
                           3.  Large coverage area.
                                                                                                                 64
                           4.  Scan components that hard to access and contact by conventional sensor.           02
                           5.  Detect leak without interrupting process.
                           6.  Remotely detect the gas.
          Output
          Industry         1.  An integration system of hardware (thermal camera) and software (automatic detection) for gas
                             leakage monitoring and detection system.
                           2.  Increase the safety issues in the oil and gas plant due to the gas leakage.

          Public Higher    1.  Exposure to the graduate internship and lecturer.
          Learning Institute

          Human Capital    1.  Enhance the knowledge to the internship students.
          Development




                                                                                                                 02

     PROBLEMS IDENTIFIED



      1.   Mostly MATLAB (image processing) programming cannot support android system.
      2.   The Seek thermal camera cannot be opened on the surface.
      3.   The selection of android type thermal camera.
      4.   Hazard level for kind of gas leakage.
      5.   Activities of transferring the knowledge to the user.
     KNOWLEDGE
           PC based is not real time. Due to limitation of installing the PC based system to the plant the system has been
      6.
           worked on offline basis.
     TRANSFERRED


     Best Practices in KTP
                                                                       PROF. DR. KAMARUL HAWARI  BIN GHAZALI
   70   71   72   73   74   75   76   77   78   79   80