Page 120 - Condition Monitor User Manual
P. 120

Viewing Measurement Data



              9.1.7.  Trend View

                          The Trend View is used to view changes in vibration over time.  To open the Trend View,
                       select the ‘Trend View’ tab. in the ribbon.
































                                                   Figure 9-16 Trend View
                          The ribbon will display the controls for manipulating the view:
                            •  In the ‘Operating Conditions’ section of the ribbon select any operating Conditions
                                to add to the graph (optional).
                            •  In the ‘Summary Number’ section of the ribbon, select which Summary Numbers
                                to add to the graph; one of these is required or the graph will be empty.
                                       Note:
                                       When trending phase changes, be sure that the Phase Quality on the
                                       trended measurements is consistently green; if there are any yellow
                                       or orange icons in the trended measurements, the phase trend will
                                       not be meaningful.


                            •  In the ‘Sensors to View’ section of the ribbon, select which axes to add to the graph;
                                one of these is required or the graph will be empty.

                          The measurement list will show all measurements; raw data is not needed to build a
                       trend.

                          Once  the  Summary  Number  and  Sensors  to  View  selection  is  made  the  graph  is
                       automatically  populated  with  all  measurements  that  are  flagged  as  ‘Trend’  in  the
                       measurement list; if no measurements are set for ‘Trend’, then no data will be displayed.
                       Any changes over time in the selected Summary Number and axes will be clear.





                                                            114
                                                                                          www.irispower.com
   115   116   117   118   119   120   121   122   123   124   125