Viewing Measurement Data
9.1.7. Trend View
The Trend View is used to view changes in vibration over time. To open the Trend View,
select the ‘Trend View’ tab. in the ribbon.
Figure 9-16 Trend View
The ribbon will display the controls for manipulating the view:
• In the ‘Operating Conditions’ section of the ribbon select any operating Conditions
to add to the graph (optional).
• In the ‘Summary Number’ section of the ribbon, select which Summary Numbers
to add to the graph; one of these is required or the graph will be empty.
Note:
When trending phase changes, be sure that the Phase Quality on the
trended measurements is consistently green; if there are any yellow
or orange icons in the trended measurements, the phase trend will
not be meaningful.
• In the ‘Sensors to View’ section of the ribbon, select which axes to add to the graph;
one of these is required or the graph will be empty.
The measurement list will show all measurements; raw data is not needed to build a
trend.
Once the Summary Number and Sensors to View selection is made the graph is
automatically populated with all measurements that are flagged as ‘Trend’ in the
measurement list; if no measurements are set for ‘Trend’, then no data will be displayed.
Any changes over time in the selected Summary Number and axes will be clear.
114