Page 8 - food store model (single storey)
P. 8

Reference Guide                                                         Fire Strategy



                   1.5.4 Travel Distances


               Approved Document B specifies the following maximum travel distances for a building of

               Shop and Commercial use:

                                                 Maximum travel distance where escape is possible in:
                                                    One direction only (m)   More than one direction (m)
                         Shop and Commercial
                                                           18m                       45m
               The graphic below shows a review of travel distance provision in the model store.
































               Figure 2-2 Travel Distance Assessment

               In this instance, the travel distance limitations for escape in two directions are satisfied. It is
               noted that a designated fire escape route should be kept clear (both Front-of-House and

               Back-of-House) and consideration should be given to the onward external escape path from
               the rear final exit. In instances where the single direction of travel cannot be met from all

               areas of the store, it may be appropriate to designate a secondary means of escape to allow
               for the assessment to take account of the provision of escape in more than one direction.



                   1.5.5 Exit Signage


               All escape routes should be distinctively and conspicuously marked by an exit sign in

               accordance with BS ISO 3864-1 and BS5499-4.






              Document Classification     Final    Document Ref:   3.1-RCS-RHSE-(110)-262   Version   1.1
                                                                                                               7
   3   4   5   6   7   8   9   10   11   12   13