Page 51 - scales manual v1014 web
P. 51
KUBOTA

KUBOTA KA-10

1. Remove the four screws that secure the metal backplate covering the CPU board
2. Slide the switch on the CPU board to the span position
3. Switch power on
4. Number displayed is deadload
5. Press the Zero Key to bring display to 0
6. Place Calibration weight and wait for stable
7. Press and hold SET key and press the SELECT key
8. Remove weight and slide cal switch

KUBOTA KA-100

1. Remove seal screw (bottom right of Indicator), use screwdriver to push button
2. “CAS”, Press MODE twice, raw counts is displayed
3. Press ZERO, Load weight(200 lbs), press SAMPLE
4. Press CAL switch, press OFF

LTS DR2100A

1. Press Scale/Zero key
2. Slide CAL switch to left
3. Press 9090 then ENTER
4. Press DEL to select YES then ENTER
5. Press DEL to select YES then ENTER
6. “Set Scale Zero”, press DEL to select YES then ENTER
7. Apply test weight, key in value then press ENTER
8. Slide CAL switch

MATKO

MATKO FLIP DIGIT

1. Apply power, hold LEARN button through countdown
2. When display goes to dashes, release LEARN button
3. Press LEARN button for 1 second
4. Display will count and eventually show 3—1 or something similar.
5. Press the LEARN button again to exit config
6. IF –01—is displayed, check wiring.
7. You may need to press the RIGHT or LEFT buttons to align the weight display.

© 2014 ScaleResource.com Page 51