Page 52 - scales manual v1014 web
P. 52
MATKO SBL 4
Indicator Pin Display Connector Pin
Out
Indicators with Active 20mA Output +20mA 6 CL+ Jump
Indicators with Passive 20 mA Output -20mA 5 CL- 1 VCC
+20mA 1 VCC 2 GND
Indicators with RS232 Output 2 GND 3 232 RXD
Indicators with RS422 Output -20mA 3 CL- 4 232TXD
TXD 4 CL+ 5 CL-
GND 6 CL+
RS422A+ 3 232RXD 7 RX 422A
RS422B- 2 GND 8 RX422B
7 RS422A 9 TX CL-
8 RS422B 10 TX CL+
11 TX 422A
12 TX 422B
13 SPARE 1
14 SPARE 2
Press the Learn button at the end of startup
MEASUREMENT SYSTEMS INTERNATIONAL
MSI 3550
1. Remove Seal port screw on the left front of the indicator and press the setup button
2. Using the USER button, scroll to CAL press TARE key
3. Press the USER button to scroll to Standard Cal and press TARE key
4. Unload scale and press ENTER(TARE)
5. Load scale and key in cal weight value, Press ENTER
6. Unload scale and press ENTER(TARE)
7. At “FCAL”, press CLEAR(ZERO)
MSI 3750
1. Remove set screw and press the Setup button
2. Using the scroll keys go to STD CAL
3. Press ENTER and clear weigh platter
4. Press ENTER, CAL’ING
5. At WEIGHT prompt, add known weight to scale
6. Key in Weight value and press ENTER
7. CAL’ING, CAL OK, STORING is displayed
8. Press the EXIT key
© 2014 ScaleResource.com Page 52
Indicator Pin Display Connector Pin
Out
Indicators with Active 20mA Output +20mA 6 CL+ Jump
Indicators with Passive 20 mA Output -20mA 5 CL- 1 VCC
+20mA 1 VCC 2 GND
Indicators with RS232 Output 2 GND 3 232 RXD
Indicators with RS422 Output -20mA 3 CL- 4 232TXD
TXD 4 CL+ 5 CL-
GND 6 CL+
RS422A+ 3 232RXD 7 RX 422A
RS422B- 2 GND 8 RX422B
7 RS422A 9 TX CL-
8 RS422B 10 TX CL+
11 TX 422A
12 TX 422B
13 SPARE 1
14 SPARE 2
Press the Learn button at the end of startup
MEASUREMENT SYSTEMS INTERNATIONAL
MSI 3550
1. Remove Seal port screw on the left front of the indicator and press the setup button
2. Using the USER button, scroll to CAL press TARE key
3. Press the USER button to scroll to Standard Cal and press TARE key
4. Unload scale and press ENTER(TARE)
5. Load scale and key in cal weight value, Press ENTER
6. Unload scale and press ENTER(TARE)
7. At “FCAL”, press CLEAR(ZERO)
MSI 3750
1. Remove set screw and press the Setup button
2. Using the scroll keys go to STD CAL
3. Press ENTER and clear weigh platter
4. Press ENTER, CAL’ING
5. At WEIGHT prompt, add known weight to scale
6. Key in Weight value and press ENTER
7. CAL’ING, CAL OK, STORING is displayed
8. Press the EXIT key
© 2014 ScaleResource.com Page 52