Page 76 - scales manual v1014 web
P. 76
TOLEDO ID7

1. Mode/Service OK
2. Code 2481632>
3. Service Mode/ Scale OK
4. Scale1 OK
5. no no no no cal yes
6. Cal internal yes
7. Set internal yes
8. Cal cap no
9. Press no to set cal weight to be used

TOLEDO JAGUAR

1. Flip setup switch S2-1, or press Setup switch while entering setup
2. Enter setup by pressing the Function key then Select then Enter
3. If display is not showing “Scale Interface”, press SELECT until it does
4. Press ENTER then SELECT until “Calibration” is displayed
5. Press ENTER, “Empty the Scale”, remove weight and press ENTER
6. “Add Test Weight”, load scale and press ENTER
7. “Wgt”, key in test weight value and press ENTER
8. “Calibration Successful”, exit by pressing ESC until “Exit?”, then press ENTER

TOLEDO LYNX

1. Open indicator and flip SW1-1 in the on position (toward numbers)
2. Press the Function key then the Select key, then press ENTER
3. Press SELECT until CALIBRATION block is displayed, then press ENTER
4. “Empty Scale”, remove weight, press ENTER
5. “Add Weight”, press ENTER
6. Enter test weight value and press ENTER
7. “Cal Done”,
8. To exit setup, press ESC several times until EXIT? Is displayed then press ENTER