Page 12 - Rpt Anderson SW18 5RS_Neat
P. 12

Survey Report        Contents           Overview           Services           Internal           External           Total Est. Costs   9



       Internal


       Kitchen





















       Kitchen                             Cooker hood not externally ducted    Split sealant

















       Crack to old ceiling rose position

       Details / Defects / Issues: Yes. Items of concern have been listed below.



       Extraction


       There is a cooker hood fitted above the hob but this does not duct through an external wall. Use of domestic
       appliances can create steam and moisture and you are advised to either duct the extractor fan through an external
       wall or install a mechanical means of ventilation in line with Approved Documents F and L of the Building Regulations
       2010. This will need to be in the form of an extractor fan with a 15 minute overrun timer facility. A three pole isolation
       switch will also need to be installed.


        Estimated Costs £400-500.00