Page 13 - Rpt Anderson SW18 5RS_Neat
P. 13

Survey Report        Contents           Overview           Services           Internal           External           Total Est. Costs   10



       Sealant


       The silicone sealant to the edges of the worktop and wall tiling has split.  The existing silicone will need to be
       completely removed prior to applying a new sealant in one continuous application.  It is important to ensure that
       these areas are correctly sealed as water escaping often goes unnoticed and serious damage can be caused to walls,
       flooring and floor timbers.


        Estimated Costs £100.00




       Decoration


       The original ceiling rose has been removed and the plaster finish has cracked around this feature. Any loose plaster
       should be removed, the area filled, left to adequately dry and then rubbed down and touched-in with matching paint.


        Estimated Costs £30.00



       Lounge





















       Lounge                              No ventilation to chimney breast
       Details / Defects / Issues: Yes. Items of concern have been listed below.




       Ventilation

       There is no permanent ventilation provided to the chimney breast. The chimney flue will need to be fitted with
       permanent ventilation by way of a 225mm x 225mm air brick permanently open to prevent condensation issues
       within the chimney flue and potential internal damage to the property.



        Estimated Costs £100.00
   8   9   10   11   12   13   14   15   16   17   18