Page 87 - GuardII+ Series 4208 Platform PD User Manual
P. 87

Troubleshooting



                     you will need to contact Iris Power LP Technical Support, but additional information will be
                     helpful.
                        •  Examine  the  synchronization  signal  using  an  oscilloscope.    Once  the  traces  are
                            acquired, send copies of them to Iris Power Technical Support.
                                     NOTE:
                                     If a sensor-based synchronization problem occurs, it is possible to have
                                     the monitor start collecting data again by changing the synchronization to
                                     an external source.
                                     However, if the GuardII+ cannot synchronize to the sensor signal, then
                                     there may be something wrong with the sensor and any data collected

                                     may be compromised.

              7.3.3.  External AC Synchronization Input

                        Use  this  procedure  if  the  external  synchronization  signal  is  connected  to  the  AC
                     Synchronization input on the GuardII+ AC Termination board.

                                     WARNING:
                                     When  troubleshooting  the  external  synchronization  signal,  take
                                     appropriate cautions to prevent injury due to the voltage levels that may
                                     be present.

























                                        Figure 7-14 External AC Synchronization Input
                        Check the following:
                        •  Verify that the external synchronization terminal block is fully inserted and secured.

                        •  Verify that the leads connecting to the external synchronization terminal block are fully
                            inserted and secure.

                        •  If any of the above were incorrect, fix the issue and check to see if the problem has
                            been fixed.