Page 67 - SWD Safety & Health Handbook
P. 67

10-147   Ensure tanks that may have contained flammables and
                                        combustibles have been cleaned and purged with an inert gas
                                        before welding or cutting begins.  Follow policy regarding
                                        welding or cutting on vessels and tanks that have previously
                                        held flammable or combustible material.

                                10-148   You are always responsible for following the confined space
                                        procedures when you are required to burn inside of tanks or a
                                        confined space.  In addition, be sure that you always have an
                                        ample supply of fresh air. Be very careful to close the
                                        oxygen/acetylene cylinder valve when the torch is not in use.
                                        Remove the torch from the confined space.

                                10-149   Do not leave electrode holders and cable lying around. When
                                        you have finished welding, wind up the cable on the machine.

                                10-150   Remove all welding rods from stingers when welders are not in
                                        use.

                                10-151   Try to avoid stringing leads or hoses across walkways, stairs, or
                                        “I” beams that create a hazard.

                                10-152   Do not carelessly discard the stub ends of electrodes.  They
                                        can ignite combustible materials and cause fires, cause painful
                                        burns and create serious slip, trip and fall hazards.

                                10-153   Protect, shield or guard regulators on portable carts used/stored
                                        in plant/shop areas.

                                10-154   Use flashback arrestors (reverse flow) on cutting torches.
                                        Flashback arrestors are required on torch handle and at
                                        oxygen/acetylene gauges.