Page 34 - Foam Bullet™
P. 34

Foam Bullet™


            Utility Connections


            Chemical and Air Connections for a Pair of Foam Bullets         ™

            At this point, the Foam Bullets™ have been secured in place on the equipment and the Chemical and
            Compressed Air Delivery System should be in place and operational. For the purpose of this manual,
            the Belanger® MixStir® Chemical Delivery System will be used to show how to connect the Chemical
            Solution and Compressed Air to a pair of Foam Bullets™.

             Note: If using the MixStir® Chemical Delivery Device it is recommended that it be installed as close to the
                    Foam Bullets™ as possible to ensure optimal performance.
             Note: A minimum of a 3/8” diameter airline is required for the Compressed Air Feed and the Chemical
                    Solution Feed when supplying a pair of Foam Bullets™.

               1)  Replace the 1/4” elbow fitting on the MixStir® Regulator with the supplied 3/8” elbow fitting.
               2)  Insert the 1/2" x 3/8” push in tube straight reducer into the outlet port of the Flo-Jet Pump on
                   the MixStir® Air Panel

                               MixStir® Air Pump Panel
                                                             3)  Locate the supplied 3/8” airline. The black
                                                                 airline  will  be  used  for  Compressed  Air
                                                                 and  the  clear  airline  will  be  used for the
              Connect Black Airline
               for Compressed Air                                Chemical Solution.
             Supplied 3/8” Elbow                             4)  Run the Compressed Air Line Feed from
              Fitting to replace                                 the Pneumatic Regulator on the MixStir®
                current fitting
                                                                 out to the center of the equipment where
                                                                 the Foam Bullets™ are attached.
                    Pneumatic                                5)  Run  the  Chemical  Solution  Airline  Feed
                   Regulator                                     from the Pump on the MixStir® out to the
                                                       Flo-Jet   center of the equipment where the Foam
                                                       Pump      Bullets™ are attached.
                                                             6)  Turn  on  the  MixStir®  to  verify  that  the
                                                                 chemical is getting out to the bay and to
                                                                 flush  out  any  unwanted  debris  that  may
                                                                 be in the airline.
                                                             7)  Connect  the  Chemical  Solution  and
                                               Connect Clear Airline   Compressed  Air  Main  Feed Lines to the
                                               for Chemical Solution   field supplied Tee Fittings.













                                                   Field
                                                  Supplied
                                                  3/8” Tees                                     3/8” Compressed Air
                                                                                                Main Feed Line





                                                                                                  3/8” Chemical Solution
                                                                                                  Main Feed Line