Page 36 - Foam Bullet™
P. 36

Foam Bullet™


            Utility Connections


            Chemical and Air Connections for a Set of Three Foam Bullets           ™

            At this point, the Foam Bullets™ have been secured in place on the equipment and the Chemical and
            Compressed Air Delivery System should be in place and operational. For the purpose of this manual,
            the Belanger® MixStir® Chemical Delivery System will be used to show how to connect the Chemical
            Solution and Compressed Air to a set of three (3) Foam Bullets™.

             Note: If using the MixStir® Chemical Delivery Device it is recommended that it be installed as close to the
                    Foam Bullets™ as possible to ensure optimal performance.
             Note: A minimum of a 1/2” diameter airline is required for the Compressed Air Feed and the Chemical
                    Solution Feed when supplying to three Foam Bullets™.

               1)  Replace the 1/4” elbow fitting on the MixStir® Regulator with the supplied 1/2” elbow fitting.
               2)  Locate the supplied 1/2” airlines. The black airline will be used for Compressed Air and the
                   clear airline will be used for the Chemical Solution.

                               MixStir® Air Pump Panel
                                                             3)  Run the 1/2” Compressed Air Line Feed
                                                                 from  the  Pneumatic  Regulator  on  the
               Connect Black Airline                             MixStir®  out  to  the  center  of  the
                for Compressed Air                               equipment where the Foam Bullets™ are
              Supplied 1/2” Elbow                                attached.
               Fitting to replace
                current fitting                              4)  Run  the  1/2”  Chemical  Solution  Airline
                                                                 Feed from the Pump on the MixStir® out
                                                                 to the center of the equipment where the
                     Pneumatic                                   Foam Bullets™ are attached.
                    Regulator                           FloJet
                                                        Pump   5)  Turn  on  the  MixStir®  to  verify  that  the
                                                                 chemical is getting out to the bay and to
                                                                 flush  out  any  unwanted  debris  that  may
                                                                 be in the airline.

                                                             6)  Connect  the  Chemical  Solution  and
                                                                 Compressed  Air  Main  Feed Lines to the
                                                Connect Clear Airline   supplied  1/2”  x  3/8”  three-way  divider
                                                for Chemical Solution   fittings.











                                                                     1/2"      Field
                                                                Compressed    Supplied
                                                                   Air Main   3-Way
                                                                  Feed Line   Fittings


                                                                                     1/2" Chemical Solution
                                                MixStir® Air Pump Panel,             Main Feed Line
                                                see enlarged view above

             1MANUL022        Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681   32
   31   32   33   34   35   36   37   38   39   40   41