Page 12 - Super Pumping Station
P. 12

SUPER PUMPING STATION


          Maintenance


          General

               •   Remove the belt guard; inspect the belt for proper tension and wear (Refer to the pumping
                   station section of this manual for instructions on adjusting belt tension).
               •   Check the oil level and quality in the Cat Pump. Use only Cat™ pump oil.
               •   Verify all nozzles are clean. Run a vehicle; inspect the pressure gauge on the  pumping
                   station during the high-pressure passes. The pressure should be within 150 PSI of original
                   setting. If this is NOT the case, nozzles may be worn.
                 NOTE:  REFER TO THE PUMPING STATION MANUAL TO INSURE THE PUMP PRESSURE
                        SETTINGS.