Page 13 - Super Pumping Station
P. 13
SUPER PUMPING STATION
Maintenance
Drive Belt Replacement and Tightening
CAUTION
When tightening of replacing the drive belts, check oil levels. The oil should be half way up the
sight gauge. Use ONLY Cat™ approved oil (Belanger part #1OIL300)
1) At the MCC, turn off the systems Main Disconnect and lock it out.
2) Remove the belt guard.
3) Loosen the 4 bolts on the motor support. There are two bolts on the pivot side (A1 and A2) and two
bolts on the adjustment side (B1 and B2).
A1 (Back Side) A2 (Back Side)
B1 (Front Side) B2 (Front Side)
Above image is a LOWER, RIGHT view
Bolts B1 and B2 are near adjustment bolt
4) Loosen the adjustment Jam Nut (C).
5) To replace the belts, lower the adjustment screw (D) while holding nut (E) screws with a wrench.
If you are tightening only, go to Step 7.
View of Pumping Station LOWER,
RIGHT section
E
C
D
1MANUL720 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 11