Page 43 - Flip IOCL Book.cdr
P. 43
Case 23 Date: 02.03.2020 Time: 11:45 hrs.
Incident
While preparation for Cover box up of MCC Package Condenser No.1, North side channel head cover (weighing
around 0.8T) of the condenser fell down on the floor gratings due to failure of the weld joint of the sliding link
hanging the channel cover on davit arm. Gratings and minor beam below the condenser got damaged due to the
fall of channel head cover.
Root Cause
Failure of weld joint of the sliding link on davit due to the defective material / weld joint of sliding link.
Recommendations
An SOP shall be developed incorporating the various safety measures to be taken before opening of such
covers having davit arm assembly. This SOP shall also include the various checks wrt to the visual conditions
like corrosion, visible cracks, dislodging, insufficient welding etc. in the davit arm assembly. In case, these are
not found to be in good condition, these are to be replaced / rectified and tested before putting into use.
This SOP will be applicable to existing as well as new units.
Case 24 Date: 12.09.2019 Time: 12:25 hrs.
Incident
Compressor barrel was to be dismantled and pulled out for its overhauling & maintenance job. Barrel was being
pulled out and it was in position on the guide rail. While fixing of lifting gears it was observed that the EOT
crane was not reaching the Centre of Gravity of barrel and while shifting of lifting gear (web sling) suddenly
guide rail bolt got sheared off letting the barrel part to settle over the rail. Due to this left foot of supervisor
caught in between the rail and barrel reslted in injury in his littler finger.
41