Page 538 - Workshop Manual - Aumark (BJ1051)
P. 538
04-394
Diagnosis- Central Lock
3. Checking fuse F13 (15A) to central lock controller circuit
(a) Disconnect central lock controller
connector.
4
(b) Use a multimeter to measure resistance
to ground of connector pin 3 of central
lock controller B035.
Resistance: >1MΩ
Is check result normal?
Yes > Replace fuse F13 (15A) and central lock controller assembly.
No > Replace fuse F13 (15A) and repair line to ground short between the fuse and connector pin 3
of central lock controller B035.
4. Checking fuse F/L2 (50A) to fuse F13 (15A) circuit
(a) Disconnect C101 connector.
Page 538