Page 538 - Workshop Manual - Aumark (BJ1051)
P. 538

04-394
                                                       Diagnosis- Central Lock

               3.     Checking fuse F13 (15A) to central lock controller circuit

                                                                (a)     Disconnect   central   lock   controller
                                                                        connector.













   4







                                                                (b)     Use a multimeter to measure resistance
                                                                        to ground of connector pin 3 of central
                                                                        lock controller B035.
                                                                        Resistance: >1MΩ










               Is check result normal?
               Yes >   Replace fuse F13 (15A) and central lock controller assembly.
               No >    Replace fuse F13 (15A) and repair line to ground short between the fuse and connector pin 3
                      of central lock controller B035.
               4.     Checking fuse F/L2 (50A) to fuse F13 (15A) circuit

                                                                (a)     Disconnect C101 connector.




























                                                                                                         Page 538