Page 539 - Workshop Manual - Aumark (BJ1051)
P. 539
04-395
Diagnosis- Central Lock
(b) Use a multimeter to measure resistance
to ground of connector pin 1 of C101.
Resistance: >1MΩ
Is check result normal?
Yes > Go to step 5. 4
No > Replace fuse F/L2 (50A) and repair line to ground short between the fuse and connector pin
1 of C101.
5. Checking fuse F/L2 (50A) to fuse F13 (15A) circuit
(a) Use a multimeter to measure resistance
to ground of connector pin 1 of B103.
Resistance: >1MΩ
Is check result normal?
Yes > Replace fuse F/L2 (50A).
No > Replace fuse F/L2 (50A) and repair line to ground short between connector pin 1 of B103
and fuse F13 (15A).
Page 539