04-395
                                                       Diagnosis- Central Lock

                                                                (b)     Use a multimeter to measure resistance
                                                                        to ground of connector pin 1 of C101.
                                                                Resistance: >1MΩ












               Is check result normal?
               Yes >   Go to step 5.                                                                                4
               No >    Replace fuse F/L2 (50A) and repair line to ground short between the fuse and connector pin
                      1 of C101.
               5.     Checking fuse F/L2 (50A) to fuse F13 (15A) circuit

                                                                (a)     Use a multimeter to measure resistance
                                                                        to ground of connector pin 1 of B103.
                                                                        Resistance: >1MΩ











               Is check result normal?
               Yes >   Replace fuse F/L2 (50A).
               No >    Replace fuse F/L2 (50A) and repair line to ground short between connector pin 1 of B103
                      and fuse F13 (15A).