BR-34                        Brake system – service brake (air pressure)


                                                          b.  Install  all  the  air  pipes  of  the  four-circuit  protection
                                                          valve  according  to  the  marks  made  when  removed  and
                                                          tighten their connector nuts.










              5. Start the engine and check the pressure of braking system to see if the air hose joint leaks.