               1.2.36  Specified Items & Prior Quotations

                         The Electrical Contractor is to be responsible for ensuring that all specified items comply
                         fully with all aspects of the  Tender Specification  for technical, commercial and
                         programming matters.

                         The Electrical Contractor must also satisfy himself that all contractual conditions between
                         himself and the manufacturer/supplier do not conflict with the Contract conditions.

               1.2.37  Restrictions and Special Requirements

                         Employees of the  Electrical Contractor are to comply with any restrictions and special
                         requirements as detailed in the Tender Specification  and or main contract conditions
                         where conflict arises the Electrical Contractor is to bring this to the attention of the
                         Project Manager for clarification prior to the submission of his tender.

                         The Electrical Contractor is to make himself aware of any Asbestos or pollution present on
                         site from the Health and safety file.

                         All due allowance is to be made for out of hours working as required for the full and
                         complete execution of the works.

                         Where out of normal hours working is required the PM is to receive not less than 2
                         working days notice specifying times and locations of the work to be undertaken. Any
                         concealed work executed during this time, for which notice has not been given, may be
                         required to be opened up for inspection and re-instated at the  Electrical Contractor's
                         expense.
               1.2.38  Deleterious Materials


                         The  Electrical Contractor is to ensure that during the execution of the works or any
                         subsequent works, he does not use or authorise the use of the following deleterious
                         materials, or those known to the Electrical Contractor to fall into this category at the time
                         of the works.
                         During the execution of the works, if the Electrical Contractor or his staff become aware
                         of deleterious materials as listed below, they must advise the PM immediately in writing:-

                        •   High alumina cement or its use in concrete
                        •   Wood wool slabs in permanent formwork to concrete or in structural elements or anywhere
                            else
                        •   Calcium chloride or sodium in admixtures for use in reinforced concrete
                        •   Calcium silicate bricks, blocks or tiles, calcium chloride;
                        •   Concrete that may be susceptible to alkali/silica reaction