Page 122 - Feed Lab
P. 122
Laboratory Water Suguna Management System Ver 1.0 / SOP / FQL / P2 - 33 Page 3 of 3
Picture - 11 Picture - 12
Picture - 13
CALCULATION
OD sample x mg of Std. Urea x 100 x 100
% Urea = ------------------------------------------------------------------------
OD std. x aliquot x 1000 x sample weight, g
OD std = OD of Standard which is nearer to OD sample
REFERENCE
AOAC official method 967.07
AOAC 16th edition, JAOAC 50, 56 (1967)
Prepared by : Approved by :
110 Director - Technical